SHF series cartridge filter
ZMFT's SHF series capsule filter element is produced in a 100000 level clean workshop throughout the entire process, strictly adhering to the dual quality systems of ISO13485 and IOS9001. The biological, physical, and chemical properties of various membrane materials have passed national testing. Widely used in fields such as biopharmaceuticals and medical equipment matching.
Category
Bag filter element
Accessories
Detail
ZMFT's SHF series capsule filter element is produced in a 100000 level clean workshop throughout the entire process, strictly adhering to the dual quality systems of ISO13485 and IOS9001. The biological, physical, and chemical properties of various membrane materials have passed national testing. Widely used in fields such as biopharmaceuticals and medical equipment matching.
Features and advantages
- Low precipitate
- Compact structure with no dead corners inside design
- Ready to throw design, convenient and practical
- Absolute precision filter membrane, each piece undergoes independent integrity testing before leaving the factory
- Sealing: High standards of quality assurance and cleanliness are used in the production process of bag filters
- Seek. The production and manufacturing process is consistent with the requirements of ISO 13485:2016.
Typical Applications
- Sterilization and filtration of SVP
- Flow cytometry sheath liquid sterilization and filtration
- Immune analyzer liquid path impurity and bacteria removal filtration
- Biological products, buffer sterilization and filtration
- Feed liquid filtration
- Sterilization and filtration of medical purified water
Operation condition
- Maximum allowable pressure (liquid): 3.5 bar@23 ℃; three bor@60
- Maximum allowable pressure (gas): 3.0 bar@23 ℃:; two point five bar@60 ℃
- Maximum allowable temperature: 60 ℃
Material structure
- Filter materials: PES, PTFE, Nylon, PP, Mce, etc
- Center rod, outer frame, and end cover: polypropylene
- Diversion layer: polypropylene
- Gaskets and gaskets: silicone rubber, fluororubber, EPDM, wrapped with PTFE
Biosafety
- Endotoxin: < 0.25EU/ml
- Dissolved matter: ≤ 50mg/10 inches
Specifications and dimensions
- Shell diameter (mm): Φ seventy
- Length: 2.5 "/5"/10“
Interface method
- Hose barb
- Imported: 13.6mm
- Outlet: 13.6mm
Filtering accuracy( μ m)
- 0.1,0.22,0.45,0.65,0.8,1.2,3.0, 5.0
Flow characteristics

Ordering Information
|
SHF |
S |
E |
0022 |
10 |
5 |
||||||
|
code |
types of |
code |
material quality |
code |
level |
code |
Accuracy( μ m) |
code |
Length (inches) |
code |
sealing ring |
|
SHF |
Hose barb |
P |
PP |
B |
food |
0010 |
0.1 |
2 |
2.5 |
S |
silica gel |
|
SNF |
NPT |
M |
MCE |
E |
electron |
0022 |
0.22 |
05 |
5 |
E |
EPDM |
|
STF |
Tri-clamp |
N |
Nylon |
P |
pharmacy |
0045 |
0.45 |
10 |
10 |
|
|
|
SPF |
Pagoda joint |
S |
PES |
C |
chemical industry |
0065 |
0.65 |
|
|
|
|
|
|
|
T |
PTFE |
|
|
0100 |
1.0 |
|
|
|
|
|
|
|
TL |
Hydrophilic PTFE |
|
|
0300 |
3.0 |
|
|
|
|
|
|
|
V |
PVDF |
|
|
0500 |
5.0 |
|
|
|
|
|
|
|
G |
GF |
|
|
1000 |
10 |
|
|
|
|
Previous
Previous
Recommended products